diff options
author | Chris Paterson <chris.paterson2@renesas.com> | 2017-12-14 09:08:39 +0000 |
---|---|---|
committer | Simon Horman <horms+renesas@verge.net.au> | 2017-12-18 12:13:36 +0100 |
commit | fcab5651fae4258a993170b7aaf443adbd3d4d84 (patch) | |
tree | ca101b308f9a0cd8e1b050f9dccde49405f56740 /scripts/show_delta | |
parent | de812613376a202d70c8ce37211044a29aae33b2 (diff) | |
download | linux-fcab5651fae4258a993170b7aaf443adbd3d4d84.tar.gz |
ARM: dts: r8a7790: Correct critical CPU temperature
The R-Car H2 hardware manual states that Tc = –40°C to +105°C. The
thermal sensor has an accuracy of ±5°C and there can be a temperature
difference of 1 or 2 degrees between Tjmax and the thermal sensor due
to the location of the latter.
This means that 95°C is a safer value to use.
Fixes: a8b805f3606f7af7 ("ARM: dts: r8a7790: enable to use thermal-zone")
Signed-off-by: Chris Paterson <chris.paterson2@renesas.com>
Reviewed-by: Geert Uytterhoeven <geert+renesas@glider.be>
Signed-off-by: Simon Horman <horms+renesas@verge.net.au>
Diffstat (limited to 'scripts/show_delta')
0 files changed, 0 insertions, 0 deletions