diff options
Diffstat (limited to 'drivers/power')
-rw-r--r-- | drivers/power/supply/bq25890_charger.c | 72 |
1 files changed, 45 insertions, 27 deletions
diff --git a/drivers/power/supply/bq25890_charger.c b/drivers/power/supply/bq25890_charger.c index 5924b036b158..050eef2571e8 100644 --- a/drivers/power/supply/bq25890_charger.c +++ b/drivers/power/supply/bq25890_charger.c @@ -529,24 +529,6 @@ static int bq25890_power_supply_get_property(struct power_supply *psy, val->intval = POWER_SUPPLY_HEALTH_UNSPEC_FAILURE; break; - case POWER_SUPPLY_PROP_CONSTANT_CHARGE_VOLTAGE: - if (!state.online) { - val->intval = 0; - break; - } - - ret = bq25890_field_read(bq, F_BATV); /* read measured value */ - if (ret < 0) - return ret; - - /* converted_val = 2.304V + ADC_val * 20mV (table 10.3.15) */ - val->intval = 2304000 + ret * 20000; - break; - - case POWER_SUPPLY_PROP_CONSTANT_CHARGE_VOLTAGE_MAX: - val->intval = bq25890_find_val(bq->init_data.vreg, TBL_VREG); - break; - case POWER_SUPPLY_PROP_PRECHARGE_CURRENT: val->intval = bq25890_find_val(bq->init_data.iprechg, TBL_ITERM); break; @@ -563,15 +545,6 @@ static int bq25890_power_supply_get_property(struct power_supply *psy, val->intval = bq25890_find_val(ret, TBL_IINLIM); break; - case POWER_SUPPLY_PROP_VOLTAGE_NOW: - ret = bq25890_field_read(bq, F_SYSV); /* read measured value */ - if (ret < 0) - return ret; - - /* converted_val = 2.304V + ADC_val * 20mV (table 10.3.15) */ - val->intval = 2304000 + ret * 20000; - break; - case POWER_SUPPLY_PROP_CURRENT_NOW: /* I_BAT now */ /* * This is ADC-sampled immediate charge current supplied @@ -628,6 +601,51 @@ static int bq25890_power_supply_get_property(struct power_supply *psy, val->intval = bq25890_find_val(bq->init_data.ichg, TBL_ICHG); break; + case POWER_SUPPLY_PROP_VOLTAGE_NOW: /* V_BAT now */ + /* + * This is ADC-sampled immediate charge voltage supplied + * from charger to battery. The property name is confusing, + * for clarification refer to: + * Documentation/ABI/testing/sysfs-class-power + * /sys/class/power_supply/<supply_name>/voltage_now + */ + ret = bq25890_field_read(bq, F_BATV); /* read measured value */ + if (ret < 0) + return ret; + + /* converted_val = 2.304V + ADC_val * 20mV (table 10.3.15) */ + val->intval = 2304000 + ret * 20000; + break; + + case POWER_SUPPLY_PROP_CONSTANT_CHARGE_VOLTAGE: /* V_BAT user limit */ + /* + * This is user-configured constant charge voltage supplied + * from charger to battery in second phase of charging, when + * battery voltage reached constant charge voltage. + * + * This value reflects the current hardware setting. + * + * The POWER_SUPPLY_PROP_CONSTANT_CHARGE_VOLTAGE_MAX is the + * maximum value of this property. + */ + ret = bq25890_field_read(bq, F_VREG); + if (ret < 0) + return ret; + + val->intval = bq25890_find_val(ret, TBL_VREG); + break; + + case POWER_SUPPLY_PROP_CONSTANT_CHARGE_VOLTAGE_MAX: /* V_BAT max */ + /* + * This is maximum allowed constant charge voltage supplied + * from charger to battery in second phase of charging, when + * battery voltage reached constant charge voltage. + * + * This value is constant for each battery and set from DT. + */ + val->intval = bq25890_find_val(bq->init_data.vreg, TBL_VREG); + break; + case POWER_SUPPLY_PROP_TEMP: ret = bq25890_field_read(bq, F_TSPCT); if (ret < 0) |