diff --git a/content.tex b/content.tex
index d68cfaf..b2ebbe2 100644
--- a/content.tex
+++ b/content.tex
@@ -691,6 +691,8 @@ The fields are interpreted as follows:
#define VIRTIO_PCI_CAP_PCI_CFG 5
/* Shared memory region */
#define VIRTIO_PCI_CAP_SHARED_MEMORY_CFG 8
+/* Vendor-specific data */
+#define VIRTIO_PCI_CAP_VENDOR_CFG 9
\end{lstlisting}
Any other value is reserved for future use.
@@ -1099,6 +1101,80 @@ The region defined by the combination of the \field {cap.offset},
The \field{cap.id} MUST be unique for any one device instance.
+\devicenormative{\paragraph}{Device-specific configuration}{Virtio Transport Options / Virtio Over PCI Bus / PCI Device Layout / Shared memory capability}
+
+The region defined by the combination of the \field {cap.offset},
+\field {cap.offset_hi}, and \field {cap.length}, \field
+{cap.length_hi} fields MUST be contained within the declared bar.
+
+The \field{cap.id} MUST be unique for any one device instance.
+
+\subsubsection{Vendor data capability}\label{sec:Virtio
+Transport Options / Virtio Over PCI Bus / PCI Device Layout /
+Vendor data capability}
+
+The optional Vendor data capability allows the device to present
+vendor-specific data to the driver, without
+conflicts, for debugging and/or reporting purposes,
+and without conflicting with standard functionality.
+
+This capability augments but does not replace the standard
+subsystem ID and subsystem vendor ID fields
+(offsets 0x2C and 0x2E in the PCI configuration space header)
+as specified by \hyperref[intro:PCI]{[PCI]}.
+
+Vendor data capability is enumerated on the PCI transport
+as a VIRTIO_PCI_CAP_VENDOR_CFG capability.
+
+The capability has the following structure:
+\begin{lstlisting}
+struct virtio_pci_vndr_data {
+ u8 cap_vndr; /* Generic PCI field: PCI_CAP_ID_VNDR */
+ u8 cap_next; /* Generic PCI field: next ptr. */
+ u8 cap_len; /* Generic PCI field: capability length */
+ u8 cfg_type; /* Identifies the structure. */
+ u16 vendor_id; /* Identifies the vendor-specific format. */
+ /* For Vendor Definition */
+ /* Pads structure to a multiple of 4 bytes */
+ /* Reads must not have side effects */
+};
+\end{lstlisting}
+
+Where \field{vendor_id} identifies the PCI-SIG assigned Vendor ID
+as specified by \hyperref[intro:PCI]{[PCI]}.
+
+Note that the capability size is required to be a multiple of 4.
+
+To make it safe for a generic driver to access the capability,
+reads from this capability MUST NOT have any side effects.
+
+\devicenormative{\subsection}{Vendor data capability}{Virtio
+Transport Options / Virtio Over PCI Bus / PCI Device Layout /
+Vendor data capability}
+
+Devices CAN present \field{vendor_id} that does not match
+either the PCI Vendor ID or the PCI Subsystem Vendor ID.
+
+Devices CAN present multiple Vendor data capabilities with
+either different or identical \field{vendor_id} values.
+
+The value \field{vendor_id} MUST NOT equal 0x1AF4.
+
+The size of the Vendor data capability MUST be a multiple of 4 bytes.
+
+Reads of the Vendor data capability by the driver MUST NOT have any
+side effects.
+
+\drivernormative{\subsection}{Vendor data capability}{Virtio
+Transport Options / Virtio Over PCI Bus / PCI Device Layout /
+Vendor data capability}
+
+The driver SHOULD NOT use the Vendor data capability except
+for debugging and reporting purposes.
+
+The driver MUST qualify the \field{vendor_id} before
+interpreting or writing into the Vendor data capability.
+
\subsubsection{PCI configuration access capability}\label{sec:Virtio Transport Options / Virtio Over PCI Bus / PCI Device Layout / PCI configuration access capability}
The VIRTIO_PCI_CAP_PCI_CFG capability